Conversion of a residential and commercial building, Kirchgasse 72–76, Wiesbaden

Standort

Wiesbaden

Bauherr

Aachener Grundvermögen Kapitalverwaltungsgesellschaft mbH, Cologne

Architekt

Zaeske und Partner Architekten BDA, Wiesbaden

Besonderheiten & Herausforderungen

1. Additional Technical Contract Conditions (ZTV) – facade

These define the minimum quality requirements and technical specifications:

  • Building physics: Requirements for thermal insulation (winter and summer), moisture protection (wind and water tightness) and sound insulation.
  • Construction technology: Guidelines on fire protection (non-combustible materials A1/A2), structural design (deflection limits), building tolerances and corrosion protection.
  • Materials & finishes: Specifications for steel (galvanising, paint coating), aluminium (alloys, anodising, powder coating), various sealants, plastics and natural stone (including anchoring methods).
  • Glazing: Requirements for insulating glass, laminated safety glass (VSG), heat-strengthened glass (TVG) and heat-soaked toughened safety glass (ESG-H).
  • Hardware: Quality requirements and functional guarantees for concealed window and door hardware (including panic hardware to DIN EN).

2. Special preliminaries & site logistics

Rules governing the organisational and commercial framework of the trade:

  • Tender documents: Obligation to submit a cost breakdown, product details, an outline programme and an installation concept.
  • Site logistics: Notes on the confined inner-city location (just-in-time delivery, maximum of two containers).
  • Scaffolding & cleaning: The scaffold is provided by the client; daily broom-clean coarse cleaning is to be carried out by the contractor.
  • Ancillary costs: Flat-rate deductions for construction insurance (0.25%) and site logistics such as electricity and water (0.45%) from the net contract sum.
  • Security: Resistance class RC2 is defined as the minimum standard for all facades at ground-floor level.

3. Specification of works

Detailed execution requirements for the individual trade sections:

  • Metalwork: This includes aluminium punched-window constructions (e.g. type LF1 for Kirchgasse 72 as a post-and-beam facade with an integrated smoke-extraction louvre window, and type LF2 for Kirchgasse 74 with a sliding door system), door constructions, and sheet metal and connection works.
  • Trade overview (section 1): Glazing works, solar shading works (external venetian blinds), natural stone works, aluminium and timber windows, cleaning works and other services (e.g. lightning protection, scaffold anchors, shop drawings).
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.