ZDMG – new research building, Centre for Digital Medicine and Health, Munich

Standort

Munich

Besonderheiten & Herausforderungen

1. Facade works

The building’s facade is divided into various types of construction depending on the building area:

  • Post-and-beam facades: aluminium constructions from the ground floor to the third floor as well as in the area of roof skylights.
  • Ceramic claddings: rear-ventilated ceramic facade with vertically structured ceramic panels on the main building volumes (first to third floors).
  • Rendered facades: rear-ventilated rendered facade on carrier boards in the recessed plinth storey (ground floor and partly first floor).
  • Metal claddings: rear-ventilated sheet-metal panel cladding on the plant room on the fourth floor as well as on plinth zones and shafts.
  • Roof skylights: skylight constructions in the atrium and above the first and fourth floors.
  • Solar shading & blackout: integrated external venetian blind systems (external solar shading) as well as internal anti-glare and blackout systems.
  • Photovoltaic elements: integrated on the south side of the plant room on the fourth floor.
  • Noise-barrier wall: a wall of sound-insulating louvres on a steel substructure in the northern area of the services storey (fourth floor).

2. Scaffolding works

Various types of scaffolding are erected to carry out the works:

  • Facade scaffolding on the main building and eastern extension building
  • Interior scaffolding / mobile scaffold towers (e.g. in the “Communication” room on the ground floor)
  • Atrium scaffolding with a full-area top working level
  • Loading platforms and a materials hoist on the south side

3. Associated planning and engineering services

Before and during the construction, the contractor must carry out the following services:

  • Workshop and installation planning including structural calculations and verification for all constructions.
  • Construction-deadline and construction-time scheduling.
  • Engineering measurement and surveying of the structural shell.
  • Calculated verification (facade U-values and sound-insulation requirements).
  • Sampling of all visible surfaces (hand samples for profiles, glass, ceramic panels, etc.).
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.